Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Certification: | CCC, ISO9001, RoHS, CE, SAA |
Still deciding? Get samples of US$ 360/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | TTN Max-7.2kw | TTN Max-8.2kw | TTN Max-10.2kw | ||
phase | 1-Phase | ||||
maximum pv input power | 8200w | 8200w | 5400w+5400w | 10200w | 5400w+5400w |
rated output power | 7200w*7200va | 8200w/8200va | 10200w/10200va | ||
maximum solar charging current | 140A | 160A | 160A | ||
Grid-tie operateion | |||||
Pv Input (DC) | |||||
Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | ||||
Start-up Voltage / Initial Feeding Voltage | 90VDC/120VDC | ||||
MPPT Voltage Range | 90-450VDC | ||||
Maximum Input Current | 1/23A | 1/23A | 2/18A | 1/23A | 2/18A |
Nominal Output Voltage | 220/230/240vac | ||||
Output Voltage Range | 195.5-253vac | ||||
Nominal Output Current | 31.3A | 35.6A | 44.3A | ||
Power Factor | >0.99 | ||||
EFFICIENCY | |||||
Maximum Conversion Efficiency (DC/AC) | 98% | ||||
TWO LOAD OUTPUT POWER | |||||
Full Load | 7200W | 8200W | 10200W | ||
Maxium Main Load | 7200W | 8200W | 10200W | ||
Maxium Second Load(battery mode) | 2400W | 2733W | 3400W | ||
Maxium Load Cut Off Voltage | 52VDC | 526VDC | 52VDC | ||
Maxium Load Return Voltage | 54VDC | 54VDC | 54VDC | ||
Off-grid operation | |||||
Ac Input | |||||
Ac star-up voltage /ac restart voltage | 120-140VAC/180VAC | ||||
Acceptable input vloltage range | 90-280VAC or 170-280vac | ||||
Frequency range | 49-51+-1HZ | ||||
Maximum ac input current | 40A | 40A | 50A | ||
Pv Input (DC) | |||||
Nominal DC Voltage/Maximum DC Voltage |
360/500VDC | ||||
MPPT Voltage Range | 90-45VDC | ||||
Maximum Input Current | 1/23A | 1/23A/2/18A | 1/23A | 2/18A | |
BATTERY MODE OUTPUT (AC) | |||||
Nominal Output Voltage | 220/230/240VAC | ||||
Output Waveform | pure sine wave | ||||
Efficiency (DC to AC) | 94% | ||||
BATTERY & CHARGER | |||||
Nominal DC Voltage | 48VDC | ||||
Maximum Solar Charging Current | 140A | 160A | 160A | ||
Maximum AC Charging Current | 120A | 140A | 140A | ||
Maximum Charging Current | 140A | 160A | 160A | ||
HYBRID OPERATION | |||||
PV Input(DC) | |||||
Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | ||||
Start-up Voltage / Initial Feeding Voltage | 90VDC/120VDC | ||||
MPPT Voltage Range | 90-450VDC | ||||
Maximum Input Current | 1/23A | 1/23A | 2/18A | 1/23A | 2/18A |
GRID OUTPUT (AC) | |||||
Nominal Output Voltage | 220/230/240vac | ||||
Output Voltage Range | 190-253vac | ||||
Nominal Output Current | 31.3A | 35.6A | 44.3A | ||
AC INPUT | |||||
AC Start-up Voltage / Auto Restart Voltage | 120-140VAC/180VAC | ||||
Acceptable Input Voltage Range | 90-280VAC or 170-180vac | ||||
Maximum AC Input Current | 40A | 40A | 50A | ||
Maximum AC Charging Current | 120A | 140A | 140A | ||
General | |||||
Physical | |||||
Dimension. D x Wx H(mm) | 500*390*130 | 500*390*130 | 530*420*160 | 500*390*130 | 530*420*160 |
Carton Dimension,DX WXH(mm) | 588*463*205 | 618*463*205 | 588*463*205 | 618*463*205 | |
Net Weight (kgs) | 13.6 | 14.5 | 14.6 | 14.8 | 15 |
Gross Weight(kgs) | 14.9 | 16 | 16.1 | 16.2 | 16.5 |
INTERACE | |||||
Communication Port | RS232/RS485/WIFI/GPRS/LITHIUM BATTERR | ||||
ENVIRONMENT | |||||
Humidity | 5% to 95% relative humidity(non-condensing) | ||||
Operating Temperature | -10ºC-50ºC |